Display Meaning Possible causes  Measures S300/S700 Measures S400/S600

F02 

Overvoltage in DC Bus Link

Max. value depends on the set mains voltage

Brake energy too high

"n02" displayed beforehand. Possibly use an external braking resistor or, in the case of multiple amplifiers, connect DC links.

"n02" displayed beforehand. Possibly use an external braking resistor or, in the case of multiple amplifiers, connect DC links.

Mains voltage set too low

Set the mains voltage correctly on the Basic Setup screen page

Set the mains voltage correctly on the Basic Setup screen page

Brake resistor configured incorrect

Set the details for the internal or external braking resistor correctly on the Basic Setup screen page

Set the details for the internal or external braking resistor correctly on the Basic Setup screen page

Brake resistor wired incorrect

Check the wiring (see instructions manual). Internal braking resistor: Bridge must be present on the connector!

External braking resistor: Bridge must be removed from the connector! 

Check the wiring (see instructions manual). Internal braking resistor: Bridge must be present on the connector!

External braking resistor: Bridge must be removed from the connector! 

Fuse in brake resistor defect

Replace fuse

Replace fuse

Braking ramps too short

Extend the braking ramps on the  Velocity Loop screen page

Extend the braking ramps on the  Velocity Loop screen page

DC Bus not linked to other amplifiers

In the case of multiple amplifiers from the same family, connect the DC links (see instructions manual)