S700 Hardware Revision Number | 24 Mar 2017 | |

S700 Hardware Revision Number

Following are tables for the required firmware versions for S700 drives based on their Hardware Revision.

S701y2...724y2 (STO Dual Channel)

Hardware RevisionFirmware VersionDateRemarksExport Classification
02.105.18 - 5.992010-02STO dual channel(S7xxy2), Memory card usable, certified safety, part number scheme changedAL-3A225
02.205.18_ND1 - 5.99_ND12014-12Dual use, new data structureAL-3A225
02.205.18_ND0 - 5.99_ND02014-12Non Dual use, new data structure-
02.30>=6.00_ND1*2017-04Dual use, single-cable motor connection possible, memory increasedAL-3A225
02.30>=6.00_ND0*2017-04Non Dual use, single-cable motor connection possible, memory increased-
For Firmware downgrade < 5.45 please contact your service partner

* can be downgraded to 5.45 - 5.99

S748/772

Hardware RevisionFirmware VersionDateRemarksExport Classification
01.01>= 5.002009-07Starting versionAL-3A225
02.10>= 5.182011-09certified safety, part number scheme changedAL-3A225
02.205.18_ND1 - 5.99_ND12014-12Dual use, new data structureAL-3A225
02.205.18_ND0 - 5.99_ND02014-12Non Dual use, new data structure-
02.30>=6.00_ND1*2017-04Dual use, single-cable motor connection possible, memory increasedAL-3A225
02.30>=6.00_ND0*2017-04Non Dual use, single-cable motor connection possible, memory increased-
For Firmware downgrade < 5.45 please contact your service partner

S701y1...724y1 (STO single channel), old product

Hardware RevisionFirmware VersionDateRemarksExport Classification
00.202.212007-01Starting version (S7xxy1)AL-3A225
01.212.50 to 3.492007-07short housing, X5,X6,X7 changedAL-3A225
02.003.50 to 4.992008-04X0/X8 inverted, EtherCAT onboard, charging circuit(parallel connectivity), single channel STOAL-3A225
02.10 (frozen)5.15 (frozen)2010-12 (frozen)Single Channel STO (S7xxy1), frozenAL-3A225