S200 Drive + Incremental with hall | 08 Sep 2016 | |

S200 Drive + Incremental with hall

Hello.

We tried incremental with hall on S200 Drive to check if it has encoder fault

, such as removing encoder signal line, removing connector and removing encoder header.

When we tried removing encoders, except hall sensor, it has no fault.

Please check about it.

Thank you.

Comments & Answers

kenny.hampton@… said ...

kenny.hampton@… |



 

You are correct, if you are using an incremental encoder with the S200, it does not report a encoder feedback fault if the encoder is removed.

 