Skip to main content

Kollmorgen Support Network

AKMH Connectorized Version Introduction >

This application note provides an introduction to “connectorized” AKMH motors and mating cables.

Debugging Intermittent EtherCAT Communication Issues >

The following fault, error, and alarm are each indicative of possible cable or connection problems. F125 on the AKD, "Fieldbus Sync frames lost." E30 in KAS, "EtherCAT communication failure during operational mode." A38 in KAS, "EtherCAT missed…

CD Series 5 C9 Extended IO Connector >

There were some discrepancies in the old literature with pinouts and no details as to a mating connector. The PDF clarifies these details.

M12 Connector DRIVE-CLiQ >

Kollmorgen does not offer mating connectors or cables for the feedback system with DRIVE-CLiQ Interface. Please use Standard cables recommended by Siemens. M12 Connector Pinout (built into the motor) Encoder (Feedback codes MA, MB)

Eight (8) Pin AC Synchronous Motor Connections >

Superior Electric manufactured an 8 pin integral connector for the AC Synchronous SS Series motors. The connections are to B, F & G, with B being the center tap or Neutral connection.

AKD X10 Primary Mating Connector - 15-Pin Male High Density D-Sub breakout board >

Kollmorgen does offer a Male 15-pin High-Density D-Sub connector with breakout board. Customers can use this for the X10 Feedback primary connector on AKD units. This type of connection is convenient for wiring non-standard cables, or non-Kollmorgen…

Power Connector S300 - S700 >

   Used with  S300, voltage type 230V S400   Used with 

Cables >



Hybrid Motor Connector AKD-N >

View Contact Socket Dimensions Technical Data   Power